Resolve your density measurement with performance

MVS2pro is a robotized system for the determination of the Density or the Standard Absolute Volumic Mass (MVS) of polymers by the principle of the Hydrostatic Push opportunely corrected to obtain the result expressed in the MV (S) unit.

MVS2pro determines the Volumic Mass in a completely automated cycle that replaces the old system used for this measure (Gradient Columns), that was characterized by typical human errors and slowness in measurement.

MVS2Pro Density System
Request Info/Quote

MVS2pro System

It is perfectly integrated in the quality Standard Process ISO9001. It’s already supported by all the control procedures for the carried-out measures.

  • 1 certified Volume Standard
  • 1 polymer standard
  • 1 standard Temperature (certificated thermometer)

MVS2pro was born for the determination of VS on High Density Polyethylene (HDPE) but it is obviously usable for the same kind of determination with other kind of materials can be analysed with the method of the hydrostatic push.

Integral control of the MVS2pro system takes place via LAN from a software console (included in the price) that is installed on a PC in the corporate network (or, with a direct connection to the PC). The software console allows you to control the system and keeps DB archive of all historical data and all the measurements made to obtain it. It is possible to recalculate archived data with other types of applications like Excel, Access and transfer them directly to LIMS.

MVS2pro includes also a dual door and a dual controlled Atmosphere Purification System (not included in basic configuration). The APS System helps purify the atmosphere from volatile molecules for greater environmental security and to stabilize the air of the measurement chamber. This system with the double dual door allows speeding up the measure and increasing the reproducibility. 

Benefits and Advantages

ACCURACYFULLY AUTOMATIC
REPRODUCIBILITYISO 1183 COMPLIANT
EASY TO USEHIGH QUALITY & QUICK MEASUREMENT
PRECISION4.0 INDUSTRY READY
  • MVS2pro is much more affordable of old Gradient Column.
  • This system is not Influenced from the experience of the user that instead influence so much the value of the measure from Gradient Column.
  • It is very Fast referred the old Gradient Column Method (40 minutes instead of 8 hours).
  • We Suggest using an Hydraulic press (normally present in the Lab) to prepare a “Standard Sample” following the ISO293, It’s impossible with the Gradient Column.
Request Info/Quote

Browse by